Taylor-wharton XL-65HP (with dual regulators) Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Taylor-wharton XL-65HP (with dual regulators). Taylor-Wharton XL-65HP (with dual regulators) User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Instructions for
XL-65 and XL-65HP
with Dual Regulator
Do not attempt to use or maintain this
unit until you read and understand these
instructions. Do not permit untrained
persons to use or maintain this unit. If
you do not fully understand these
instructions, contact your supplier for
further information.
TW-289
Vedere la pagina 0
1 2 3 4 5 6 ... 25 26

Sommario

Pagina 1 - XL-65 and XL-65HP

Instructions forXL-65 and XL-65HPwith Dual RegulatorDo not attempt to use or maintain thisunit until you read and understand theseinstructions. Do not

Pagina 2 - INFORMATION

Pressure Transfer Filling Procedure (Low Pressure Source) – Once you have deter-mined the proper full weight for a container, connect a transfer hose

Pagina 3 - SPECIFICATIONS

In use, the CGA Tailpiece couples to the fill connection on the container being filled. TheRelief Valve vents pressure over 350 psig (24 bar/2413 kPa)

Pagina 4 - Containers

WARNING:Never put any liquidcylinder into anotherservice once it has beenin CO2 service.WARNING:For O2 System users:Residue of leakdefectors solutions

Pagina 5 - OPERATION

3. Install new fittings for the USE, VENT and LIQUID connections form the Gas ServiceChange Kit. Leak test the fittings you just replaced, and change

Pagina 6 - Flow Diagram

NOTE:The regulator hasdirectional gas flow.The arrow on theregulator body mustpoint in directionindicated in the BenchAdjustment Fixtureillustration.R

Pagina 7 - Building Rates

CHECKING CONTAINER PERFORMANCECryogenic containers are two containers, one within the other. The space between thecontainers acts as a highly efficien

Pagina 8 - Liquid Withdrawal

WARNING:Cold surfaces shouldnever be handledwith bare skin. Usegloves and otherprotective clothingwhen performing thisprocedure.FULL VIEW CONTENTS GAU

Pagina 9 - 2 before

NOTE:The yellow band willmove approximately ¼in. (6/4 mm) to each 10turns on the rod.NOTE:Remember thisprocedure is performedwith gauge in an upright(

Pagina 10 - Pressure Source

6. When you are satisfied that the float rod correctly installed, lower the assembly therest of the way into the container until the top portion threa

Pagina 11 - Fill Hose Kits

HAND VALVE REPAIRHand valves are an integral par of the container and the valve bodies rarely need replace-ment. However, the handwheel and internal p

Pagina 12 - MAINTENANCE

Pressure Hazard – The containers covered by this literature may contain pressures up to350 psig (24 bar/2412 kPa). Sudden release of this pressure may

Pagina 13

Valve Replacement Instructions1. Partially thread Seat Assembly (12) (seat disc first) into large end of Bushing (13)leaving tan of nipple assembly ex

Pagina 14 - Adjustment

The following chart is provided to give you some guidance in determining the probablecause and suggested corrective action for some problems that may

Pagina 15

TROUBLESHOOTING CHARTSymptom Possible Cause Corrective ActionContainer is cold and 1. Vacuum loss. Check NER. 1. Consult with Taylor-Whartonmay have i

Pagina 16 - Full View Contents

This replacement parts list includes a recommended inventory quantity which allows youto order parts on a timely basis to keep all your XL-65/65HP con

Pagina 17 - Calibration

Accessories available for use with Taylor-Wharton XL Series containers are:-Manifolds, Automatic and Manual-Container Hand Trucks-Vaporizers adding up

Pagina 18 - Insertion

Index RecommendedNo. Description Part No. For 10 Units1. Dual Regulator, Pressure Building/Economizer 6999-9018 2 Each300 psig (20.9 bar/2068 kPa)Dual

Pagina 19 - Exploded View

Index RecommendedNo. Description Part No. For 10 Units17.- VENT (CGA 440) - oxygen 6514-8992 5 Each- VENT (CGA 295) - argon/nitrogen 7355-4712 5 Each-

Pagina 20

XL-65 XL-65HPDimensionsDiameter 26 in. (660 mm) 26 in. (660 mm)Height* 59 1/4 (1505 mm) 59 1/4 (1505 mm)Weight, Empty5 Caster Base 375 lb. (170 kg) 46

Pagina 21 - TROUBLESHOOTING

Handling the ContainerThe XL Series containers are very rugged liquid cylinders. All cryogenic liquid containershave an inner container and an outer c

Pagina 22

OPERATIONXL-65 and XL-65HPComponentLocationsThe XL-65/65HP will store up to 240 liters of product. The two cylinders can deliver eitherliquid or gas.

Pagina 23 - REPLACEMENT

XL-65 and XL-65HPFlow DiagramNote:The economizer andpressure buildingfunctions arecontrolled by a singledual action regulator.The pressure deltabetwee

Pagina 24 - ACCESSORIES

CAUTION:When withdrawinggas from the cylinder,the capacity of theinternal vaporizer canbe exceeded. If gas iswithdrawn at ratesgreater than thevaporiz

Pagina 25 - ° GL45-9C22 2 Each

WITHDRAWING GAS FROM THE CONTAINERTo withdraw gas from the XL-65/65HP connect a suitable pressure regulator to the USEconnection, and the output of th

Pagina 26 - ** Optional/Not illustrated

FILLING THE CONTAINERCryogenic liquid containers must always be filled by weight to ensure there is enough gashead space (usage) for liquid to expand

Commenti su questo manuale